• pipeline
  • pipeline

PRODUCT: VPR - 301

Tailored composite patch repair solution for localized corrosion/damage in metallic/composite structures. Ideal for refineries, power plants, steel plants, chemical industry etc.





Tailored composite patch repair solution for localized corrosion/damage in metallic/composite structures. Ideal for refineries, power plants, steel plants, chemical industry etc.

Title Info
Layer Thickness (6 layers) 3.5 mm
Tensile Modulus (Circumferential) 11.32 GPa
Tensile Modulus (Axial) 11.28 GPa
Tensile Strength (Circumferential) 232 MPa
Tensile Strength(Axial) 230 MPa
Poisson’s Ratio (Circumferential) 0.30
Poisson’s Ratio (Axial) 0.28
Service Temperature Range -30 C to 150 C
Lap Shear Strength to steel 9.81 MPa
Barcol/Shore Hardness 52.30 shore D
Title Info
½’ to 48’ In-Situ Repair Leaking Defect Pipe Size Up to 25 mm dia
½’ to 48’ Ex-Situ Repair Leaking Defect Pipe Size Any size
½’ to 48’ Part wall Loss Pipe Operating Pressure 350 bars
½’ to 48’ Through wall defect Pipe Operating Pressure 70 bars